ALQ118
LQ Relays

Product specifications for this product
Item | Product specifications |
---|---|
Contact arrangement | 1 Form C |
Max. switching current | N.O.: 10 A (125 V AC), 5 A (30 V DC)<br>N.C.: 3 A (125 V AC), 1 A (30 V DC) |
Max. switching voltage | 250 V AC, 30 V DC |
Operating function | Single side stable |
Terminal shape | PC board terminal |
Min. switching load (reference value) | 100 mA 5 V DC |
Dielectric strength (initial) : Between contact and coil | 4,000 Vrms for 1 min (detection current: 10 mA) |
Dielectric strength (initial) : Between open contacts | 750 Vrms for 1 min (detection current: 10 mA) |
Shock resistance (Destructive) | 980 m/s<sup>2</sup> (half-sine shock pulse: 6 ms) |
Shock resistance (Functional) | 196 m/s<sup>2</sup> (half-sine shock pulse: 11 ms, detection time: 10 μs) |
Vibration resistance (Destructive) | 10 to 55 Hz (at double amplitude of 2 mm) |
Vibration resistance (Functional) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 μs) |
Protective construction | Sealed |
Coil insulation class | Class B insulation |
Contact rating type | Standard type |
Conditions | Ambient temperature: -40 to +85℃ (-40 to +60℃ at our standard packing condition)<br>Humidity: 5 to 85% RH (Avoid icing and condensation) |
Contact material | AgNi type |
Packing style | Carton |
Relay shape | Slim type |
Standard packingCase (pieces) | 500 |
Rated coil voltag | 18 V DC |
Rated operating power | 400 mW |
Max. allowable voltage | 110% V of rated coil voltage (at 85℃)<br>150% V of rated coil voltage (at 20℃) |
Resistive load | [at 20℃, Switching frequency: ON:OFF=1.5 s:1.5 s with diode]<br>Form A contact: Min. 100x10<sup>3</sup> ope. 5 A 30 V DC<br>Form A contact: Min. 50x10<sup>3</sup> ope. 10 A 125 V AC<br>Form A contact: Min. 50x10<sup>3</sup> ope. 5 A 250 V AC<br>Form B contact: Min. 200x10<sup>3</sup> ope. 3 A 125 V AC<br>Form B contact: Min. 200x10<sup>3</sup> ope. 2 A 250 V AC<br>Form B contact: Min. 100x10<sup>3</sup> ope. 1 A 30 V DC |
Contact rating (resistive load) | N.O.: 10 A 125 V AC, 5 A 250 V AC, 5 A 30 V DC<br>N.C.: 3 A 125 V AC, 2 A 250 V AC, 1 A 30 V DC |
Contact resistance (initial) | Max. 100 mΩ (by voltage drop 6 V DC 1 A) |
Contact shape | Single |
Insulation resistance (initial) | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Max. switching power (resistive load) | N.O.: 1,250 VA, 150 W<br>N.C.: 500 VA, 30 W |
Mechanical life | Min. 10x10<sup>6</sup> ope. (switching frequency: at 180 times/min) |
Unit weight | Approx. 7 g |
[[Specifications]]Surge withstand voltage (initial) : Between contact and coil | 8,000 V |
Model Number | ALQ118 |
Part Number | ALQ118 |
Standard packing<br>Carton (pieces) | 100 |
[[Coil data]]Coil resistance [±10%] (at 20℃) | 810 Ω |
[[Coil data]]Operate voltage (at20℃) | Max. 75% V of rated coil voltage (Initial) |
[[Coil data]]Rated operating current [±10%] (at 20℃) | 22.2 mA |
[[Coil data]]Release voltage (at20℃) | Min. 5% V of rated coil voltage (Initial) |
[[Specifications]]Operate time (initial) (at 20℃) | Max. 20 ms at rated coil voltage (without bounce) |
[[Specifications]]Release time (initial) (at 20℃) | Max. 20 ms at rated coil voltage (without bounce, with diode) |