Item Product specifications
Contact arrangement 1 Form C x 2 (8 pins)
Operating function Single side stable
Rated coil voltage 12 V DC
Terminal shape PC board type
Vibration resistance (Destructive) 10 to 500 Hz, Min. 44.1m/s2[approx. 4.5G]
(Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours)
Vibration resistance (Functional) 10 to 100 Hz, Min. 44.1 m/s2 [approx. 4.5G] (detection time: 10µs)
Protective construction Sealed
Conditions Ambient temperature: –40 to +85°C –40 to +185°F,
Humidity: 5 to 85% R.H. (Please avoid icing or condensation)
Contact material Ag alloy
Packing style Tube
Coil resistance [±10%] (at 20°C) 180 Ω
Rated operating current [±10%] (at 20°C) 66.7 mA
Unit weight Approx. 8 g .28 oz
Dielectric strength (Between contacts and coil) (Initial) 500 Vrms for 1 min. (Detection current: 10mA)
Dielectric strength (Between open contacts) (Initial) 500 Vrms for 1 min. (Detection current: 10mA)
Inner carton (pieces) 30
Insulated resistance (Initial) Min. 100 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.)
Min. switching load (resistive) 1A 14V DC (at 20°C 68°F)
Operate (Set) time(at rated coil voltage) (at 20°C) (Initial) Max. 10ms (without contact bounce time)
Operate (Set) voltage (at20°C) (Initial) Max. 7.2V DC
Outer carton (pieces) 900
Rated operating power (at 20°C) 800 mW
Rated switching capacity (resistive) N.O.side: 20A 14V DC, N.C.side: 10A 14V DC
Release (Reset) time(at rated coil voltage) (at 20°C) (Initial) Max. 10ms (Without contact bounce time) (Without diode)
Release (Reset) voltage (at20°C) (Initial) Min. 1.0V DC
Shock resistance: Destructive Min. 1,000 m/s2 [approx. 100G] (Half-wave pulse of sine wave: 6ms)
Shock resistance: Functional Min. 100 m/s2 [approx. 10G] (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
Usable voltage range 10 to 16V DC
Model Number ACT212
Part Number ACT212
Contact resistance Max. 100mΩ (N.O. side: typ. 7mΩ, N.C. side: typ. 10mΩ) (By voltage drop 1A 6V DC) Initial
Contact data: max. carrying current N.O.side:
25A for 1 hour, 35A/2 min. (Coil applied voltage 14V DC, at 20°C 68°F)
20A for 1 hour, 30A/2 min. (Coil applied voltage 14V DC, at 85°C 185°F)
Expected life [mechanical] Min. 107 (at 120 cpm)
Expected life [electrical] [resistive] [Resistive load]
Min. 105 (at rated switching capacity, operating frequency: 1s ON, 9s OFF
[Motor load]
N.O. side: Min. 2x105 at Inrush 25A, Steady 5A 14V DC, Min. 105 at 25A 14V DC motor lock condition
N.C. side: Min. 2x105 at brake current 20A 14V DC (operating frequency: 0.5s ON, 9.5s OFF)
Show more

Downloads for this product

Name File Type Size Date Language
CT Relays, 2D CAD(DXF) Other 26.2 KB 01.01.2011 English
PDF CT Relays Datasheet Data sheet 458.3 KB 01.04.2022 English
PDF Automotive Relays Selector Chart Data sheet 341.7 KB 01.10.2022 English